Location Offshore Platform Fields |
AIR's individual risk methodology follows a structured, logical approach that groups building characteristics according to their function to reflect the contribution of each characteristic to overall building performance. For information about the secondary risk characteristics that are supported in a specific model, refer to the "Model in Touchstone” chapter in the model description, which is available on AIR's Client Portal. Documentation for some AIR models includes a separate document that serves as a guide to the secondary risk characteristics (SRC) used in the model.
The following table describes the Touchstone location fields related to offshore platforms:
Field |
Perils |
Description |
Validation Rules |
Default Value |
• US HU OS |
Complete platform definition (protraction + block + name) for this platform Enter the area/protraction, followed by the block, followed by the structure name. Separate these values by spaces. For example: SS 26 B-HTR If the PBN definition is unknown, enter X for this field. |
Required if you have not provided the MMS complex ID, MMS structure number, or AIR structure ID |
|
|
• US HU OS |
Unique AIR-assigned identifier for this platform |
Required if you have not provided the MMS complex ID, MMS structure number, or PBN definition |
|
|
• US HU OS |
Unique BOEMRE (Bureau of Ocean Energy Management, Regulation and Enforcement - formerly known as Mineral Management Survey - MMS) identifier assigned to a single structure or a group of structures connected by a walkway |
Required if you have not provided the MMS structure number, AIR structure ID, or PBN definition |
|
|
• US HU OS |
Unique BOEMRE (Bureau of Ocean Energy Management, Regulation and Enforcement - formerly known as Mineral Management Survey - MMS) number assigned to a specific structure within a complex |
Required if you have not provided the MMS complex ID, AIR structure ID, or PBN definition |
|
|
• US HU OS |
Administrative area in which this platform is located |
• Optional • Can contain up to 255 characters |
|
|
• US HU OS |
Protraction/area in which this platform is located |
• Optional • Can contain up to 255 characters |
|
|
• US HU OS |
Block in which this platform is located |
• Optional • Can contain up to 255 characters |
|
|
• US HU OS |
Replacement cost of this platform |
• Defaults to a value in the Touchstone user interface • Must be a numeric value between 0 and 999999999999999, inclusive |
0.00 |
|
• US HU OS |
Year in which this platform was built or underwent a major upgrade |
• Defaults to a value in the Touchstone user interface • Must be 0 or a numeric value between 1967 and 2067, inclusive |
0 |
|
• US HU OS |
Rate of gas that this platform produces per day, measured in Mcf (1,000 cubic feet) |
• Defaults to a value in the Touchstone user interface • Must be -1 or a numeric value greater than or equal to 0 |
0 |
|
• US HU OS |
Rate of oil that this platform produces per day, measured in barrels |
• Defaults to a value in the Touchstone user interface • Must be -1 or a numeric value greater than or equal to 0 |
0 |
|
• US HU OS |
Height of the deck of this platform above the water, measured in meters |
• Defaults to a value in the Touchstone user interface • Must be -1 or a numeric value between 0 and 999, inclusive • AIR recommends that you specify a deck height value between 0 and 999, inclusive. |
-1 |
|
• US HU OS |
Number of wells that this entity is licensed to drill |
• Defaults to a value in the Touchstone user interface • Must be -1, 300, or a numeric value between 0 and 50, inclusive • AIR recommends that you specify a slot count value between 0 and 50, inclusive. Nevertheless, if you specify a slot count value greater than 50, the model will still use it. |
-1 |
|
• US HU OS |
Number of wells currently drilled |
• Defaults to a value in the Touchstone user interface • Must be -1, 300, or a numeric value between 0 and 50, inclusive • AIR recommends that you specify a slot drill count value between 0 and 50, inclusive. Nevertheless, if you specify a slot count value greater than 50, the model will still use it. |
-1 |
|
• US HU OS |
Number of legs on this platform |
• Defaults to a value in the Touchstone user interface • Must be a numeric value between 0 and 44, inclusive |
0 |
|
• US HU OS |
Number of decks on this platform |
• Defaults to a value in the Touchstone user interface • Must be a numeric value between 0 and 10, inclusive |
0 |
|
• US HU OS |
One of the following types (or shapes) of transverse framing used to brace the legs of this platform: • 0 - Unknown • 1 - XH • 2 - X • 3 - N • 4 - KH • 5 - K • 6 - /H • 7 - / |
Defaults to a value in the Touchstone user interface |
Unknown |
|
• US HU OS |
Cost of the deck or decks and equipment on this platform |
• Defaults to a value in the Touchstone user interface • Must be -1 or a numeric value between 0 and 100, inclusive • AIR recommends that you specify a topside cost value between 0 and 100, inclusive. |
-1 |
|
• US HU OS |
One of the following values to indicate whether this platform is manned: • 0 - Unknown • 1 - Manned • 2 - Unmanned |
Defaults to a value in the Touchstone user interface |
Unknown |
|
• US HU OS |
One of the following values to describe the size of the company that operates this platform: • 0 - Unknown • 1 - Small • 2 - Medium • 3 - Large |
Defaults to a value in the Touchstone user interface |
Unknown |
|
• US HU OS |
Number of wells connected to this platform |
• Defaults to a value in the Touchstone user interface • Must be -1 or a numeric value between 0 and 100, inclusive • AIR recommends that you specify a well count value between 0 and 100, inclusive. |
-1 |
© 2020 AIR Worldwide. All rights reserved. Touchstone 7.0 Updated September 03, 2020 |