Location Surrounding Detail Fields
Validation details supported by Touchstone.
AIR's individual risk methodology follows a structured, logical approach that groups building characteristics according to their function to reflect the contribution of each characteristic to overall building performance. For information about the secondary risk characteristics (SRCs) that are supported in a specific model, refer to the "Model in Touchstone” chapter in the model description, which is available on the AIR Client Portal. Documentation for some AIR models includes a separate document that serves as a guide to the SRCs used in the model.
The following table describes the Touchstone location fields related to the surrounding detail for this location. Click the following links for information about Location Building Detail fields, such as floor of interest and floor area, and about about Location Connection Detail fields, such as Foundation Type.
Field |
Perils |
Description |
Validation Rules |
Default Value |
---|---|---|---|---|
Pounding |
|
One of the following values to describe the distance from the building at this location to the closest structure, which, if not adequate, can cause the two structures to collide during earthquake shaking:
This factor usually concerns high-rise buildings in densely built areas, like business districts of cities. If the gap between adjacent tall buildings is not adequate, there is potential danger of the two structures colliding during earthquake shaking. This phenomenon is known as the "pounding effect." Severe damage may occur when the floors of the building are at different elevations, and the impact of one building's floors can destroy the columns in the adjacent building. |
|
Unknown/default (0) |
Tree Exposure |
|
One of the following values to indicate whether tree hazard exists around the building at this location:
Trees snap in strong winds and can damage adjacent buildings. |
|
Unknown/default (0) |
Small Debris |
|
One of the following values to indicate whether there is potential for small debris within a radius of 200 feet from the building at this location:
Small debris, such as roof gravel, trash bins, or tree branches, may be picked up by high wind and breach window glass. Small debris can be carried to all elevations at high wind speed. |
|
Unknown/default (0) |
Large Missile |
|
One of the following values to indicate whether there is potential for large missiles within a radius of 100 feet from the building at this location:
Garden furniture or wood planks or studs dislodged from nearby buildings may become missiles at high wind speed and breach the building envelope. |
|
Unknown/default (0) |
Terrain Roughness |
US HU US ST - Straight-Line Winds, Tornadoes |
One of the following values to describe the terrain conditions around the building at this location:
|
|
Unknown/default (0) |
Adjacent Building Height |
|
Average height of buildings adjacent to the building at this location Express the average height as an average number of stories. A value of 0 for this field represents Unknown/default. |
|
|
Custom Flood Standard of Protection |
|
Increase in flood protection for the building at this location that custom flood protection systems, such as levees or flood walls, provide for single risks (for example, for large industrial facilities). This field represents the height of a custom flood protection system (in feet for Japan and the US, in meters for Europe) above the ground surface at the building at this location. A value of -999 for this field in your import data indicates that custom protection is not present. This value is also the default setting for this field. Touchstone does not allow any other negative values. Setting this field to "0" indicates that the basement at this location has been equipped with flood protection to a level that is equivalent to the elevation of the adjacent ground surface. If the Custom Flood SOP Type is "RP" (supported only for CE IF), the unit of this field will be in years and Touchstone will apply the corresponding Return Period protection to this location. |
|
-999 |
Custom Flood SOP Type |
CE IF |
One of the following values to indicate the type of SOP (Standard of Protection):
|
|
Unknown |
Custom Flood Zone |
|
One of the following values to indicate whether the building at this location is part of a custom flood zone:
If you specify Unknown / Default (0) as the value for this field, Touchstone assumes that no zone has been defined and includes all locations for analysis. For the AIR Inland Flood Model for Central Europe, indicates whether the building at this location is part of a custom flood zone. Defining this modifier for a location helps to filter the locations defined with custom zones to include in the analysis. This ability is especially useful if only certain zones can be included for protection. You can specify flood zones in Touchstone by clicking the pencil icon next to the Inland Flood peril selection in the Analysis Settings pane. For the AIR Inland Flood Model for the United States, indicates the FEMA flood zones in which the building at this location is located. |
|
0 |
Custom Elevation |
|
Elevation (in feet for Japan and the US, and in meters for Europe) of the local ground surface (in feet) at the building at this location This field represents the elevation of the grade (local ground surface) with respect to the datum (NAVD88) nature of finish in basements of buildings. A value of -999 for this field represents Unknown/default. The custom elevation (i.e., a value other than -999) overrides the underlying modeled digital terrain (DTM) elevation. |
|
|
Base Flood Elevation |
|
Water elevation (in feet) for a 100-year flood at the building at this location, as defined by FEMA Touchstone supports this field for all residential, commercial, and small industrial buildings. A value of -999 for this field represents Unknown/default. AIR recommends that you do not code this field as "0". FEMA defines the Base Flood Elevation (BFE) as the "water surface elevation corresponding to a flood having a 1% probability of being equaled or exceeded in a given year." Touchstone assumes that the building at this location has its lowest floor (including the basement, if any) at the BFE. |
|
|
Defensible Space |
US WF |
Area between the structure and an oncoming wildfire, where landscaping has been managed to alter or cut off the fire's path, with the intent of increasing the structure's probability of survival. A value of -999 for this field represents Unknown/default. For detailed information about this SRC, see the "Secondary Risk Characteristics for the AIR Wildfire Model for the United States document on the AIR Client Portal. |
|
-999 |
Firewise Community Participation |
US WF |
Firewise USA™ (Firewise) program is a National Fire Protection Association (NFPA) program co-sponsored by the USDA Forest Service, U.S. Department of the Interior, and the National Association of State Foresters. Recognition as a Firewise community requires numerous activities. When this SRC is enabled, the model automatically assigns defensible space a value of 100 feet unless the user specifically changed the defensible space distance. For detailed information about this SRC, see the "Secondary Risk Characteristics for the AIR Wildfire Model for the United States document on the AIR Client Portal. |
|
0 -- Unknown |